f Omron CP1 Series PLC-CUP Units CP1E- A&S Automation Co., Ltd
 
Home / PLC / Omron PLC / CPU Units / Omron CP1 Series PLC-CUP Units CP1E

Add To Cart
share
Type AC power supply models DC power supply models Model CP1E-[][][]D[]-A CP1E-[][][]D[]-D Enclosure Mounted in a panel Dimensions (H  D  W) CPU Unit with 10 I/O points (CP1E-E10D[]-[]): 90mm *1 85mm *2  66 mmCPU Unit with 14 or 20 I/O points (CP1E-[]14D[]-[]/[]20D[]-[]): 90mm *1  85mm *2  86 mmCPU Unit with 30 I/O points (CP1E-[]30D[]-[]): 90mm *1  85mm *2  130 mmCPU Unit with 40 I/O points (CP1E-[]40D[]-[]): 90mm *1  85mm *2  150 mmCPU Unit with 60 I/O points (CP1E-N60D[]-[]): 90mm *1 85mm *2  195 mmCPU Unit with 20 I/O points and built-in analog (CP1E-NA20D[]-[]): 90mm *1 85mm *2  130 mm Weight CPU Unit with 10 I/O points (CP1E-E10D[]-[]): 300g max.CPU Unit with 14 I/O points (CP1E-[]14D[]-[]): 360g max.CPU Unit with 20 I/O points (CP1E-[]20D[]-[]): 370g max.CPU Unit with 30 I/O points (CP1E-[]30D[]-[]): 600g max.CPU Unit with 40 I/O points (CP1E-[]40D[]-[]): 660g max.CPU Unit with 60 I/O points (CP1E-N60D[]-[]): 850g max.CPU Unit with 20 I/O points and built-in analog (CP1E-NA20D[]-[]): 680g max. Electricalspecifica-tions Supply voltage 100 to 240 VAC 50/60 Hz 24 VDC Operating voltagerange 85 to 264 VAC 20.4 to 26.4 VDC Power consumption 15 VA/100 VAC max.25 VA/240 VAC max.(CP1E-E10D[]-A/[]14D[]-A/[]20D[]-A) 9 W max. (CP1E-E10D[]-D)13 W max. (CP1E-N14D[]-D/N20D[]-D) 50 VA/100 VAC max.70 VA/240 VAC max.(CP1E-NA20D[]-A/[]30D[]-A/[]40D[]-A/N60D[]-A) 20 W max.(CP1E-NA20D[]-D/N30D[]-D/N40D[]-D/N60D[]-D)*4 Inrush current 120 VAC, 20 A for 8 ms max. for cold start atroom temperature240 VAC, 40 A for 8 ms max. for cold start atroom temperature 24 VDC, 30 A for 20 ms max. for cold start at roomtemperature External power supply*3 Not provided.(CP1E-E10D[]-A/[]14D[]-A/[]20D[]-A)24 VDC, 300 mA(CP1E-NA20D[]-A/[]30D[]-A/[]40D[]-A/N60D[]-A) Not provided Insulation resistance 20 M min. (at 500 VDC) between the externalAC terminals and GR terminals Except between DC primary current and DCsecondary current Dielectric strength 2,300 VAC 50/60Hz for 1 min between ACexternal and GR terminals Leakage current:5 mA max. Except between DC primary current and DCsecondary current Power OFFdetection time 10 ms min. 2 ms min. Applicationenviron-ment Ambient operatingtemperature 0 to 55 C Ambient humidity 10% to 90% Atmosphere No corrosive gas. Ambient storagetemperature -20 to 75 C (excluding battery) Altitude

Hot Products
Reviews(0)
Write a Review

Level:
 
Name:  
Reviews: