Sick KT5W-2N1316 Overview



Contrast Scanner KT5W-2N1316 NPN-Switching output Light spot orientation lengthwise, Scanning distance 40mm, without timer Teach-in, 5-pin plug M12 without analog output

Sick KT5W-2N1316 Description



  • Tough, metal housing
  • Various teach-in methods via control panel or control cable
  • Maximum detection reliability due to 3-color RGB LED technology
  • Switching frequency of 10 kHz
  • Various sensing distances and light spot directions
  • M12 plug can be rotated 90
  • Your benefits

  • All print marks and color combinations are reliably detected, ensuring high machine throughput
  • Reliable operation, even with jittering webs and high-gloss materials
  • High positioning accuracy improves packaging quality
  • Various sensing distances, light spot directions and light emissions make individual configuration and simple integration into the production process possible

Features
Dimensions (L x W x H): 80 mm x 30.4 mm x 53 mm
Sensing distance 1): 40 mm
Sensingdistance tolerance: 3 mm
Light source 2) 3): LED red, green, blue
Light emission: Long and short side of housing, exchangeable
Light spot size: 1.1 mm x 4.2 mm
Light spot direction 4): Vertical
Adjustment: Static 2-point teach-in
1) From front edge of lens 2) Average service life of 100,000 h at TA = +25 C 3) Wave length: 470 nm, 525 nm,640 nm 4) In relationto long side of housing
Mechanics/electronics
Supply voltage Vs 1): DC 10 V ... 30 V
Residual ripple 2): ≤ 5 Vpp
Power consumption 3): < 80 mA
Switching frequency 4): 10 kHz
Response time 5): 50 s
Switching output: NPN: HIGH = approx.VS/ LOW ≤ 2 V
Switching output: NPN
Input, teach-in (ET): NPN:
Teach: U < 2 V
Run: U= 10 V... < UV
Retention time (ET): 25 ms, non-volatile memory
Protection class 6): II
Circuit protection: Output Q short-circuit protected, Interference suppression, VS connections reverse-polarity protected
Enclosure rating: IP 67
Weight: Ca. 400 g
Housing material: Zinc diecast
Output current Imax.: 100 mA
1) Limit values: operation in short-circuit protected network max. 8 A 2) May not exceed or fall short of VS tolerances 3) Without load 4) With light/dark ratio 1:1 5) Signal transit time with resistive load 6) Reference voltage DC 50 V
Ambient data
Ambient temperature: Operation: -10 ... 55 C
Storage: -25 ... 75 C
Shock load: according to IEC 60068