Sick KT5G-2P2321 Overview
Contrast Scanner KT5G-2P2321 PNP-Switching output Light spot orientation across, Scanning distance 40mm, time delay 20ms 4-pin plug M12, without analog output
Sick KT5G-2P2321 Description
- Tough, metal housing
- Manual switching threshold adjustment with optical adjustment indicator
- Green or white LED technology
- Models with analog output
- Switching frequency of 10 kHz
- Various sensing distances and light spot directions
- M12 plug can be rotated 90
- All standard print marks and contrasts are detected
- Reliable operation, even with jittering webs and high-gloss materials
- High positioning accuracy improves packaging quality
- Various sensing distances, light spot directions and light emissions make individual configuration and simple integration into the production process possible
Your benefits
| Features | |
| Dimensions (L x W x H): | 80 mm x 30.4 mm x 53 mm |
| Sensing distance 1): | 40 mm |
| Sensingdistance tolerance: | 3 mm |
| Light source 2) 3): | LED green |
| Light emission: | Long and short side of housing, exchangeable |
| Light spot size: | 1.1 mm x 4.2 mm |
| Light spot direction 4): | Horizontal |
| Adjustment: | Manual adjustment, potentiometer |
| Switching mode: | Light/dark switching |
| 1) From front edge of lens 2) Average service life of 100,000 h at TA = +25 C 3) Wave length: 520 nm 4) In relationto long side of housing | |
| Mechanics/electronics | |
| Supply voltage Vs 1): | DC 10 V ... 30 V |
| Residual ripple 2): | ≤ 5 Vpp |
| Power consumption 3): | < 80 mA |
| Switching frequency 4): | 10 kHz |
| Response time 5): | 50 s |
| Switching output: | PNP: HIGH = VS-≤ 2 V / LOWapprox. 0 V |
| Switching output: | PNP |
| Time delay: | 20 ms |
| Connection type: | Connector M12, 4-pin |
| Protection class 6): | II |
| Circuit protection: | Output Q short-circuit protected, Interference suppression, VS connections reverse-polarity protected |
| Enclosure rating: | IP 67 |
| Weight: | Ca. 400 g |
| Housing material: | Zinc diecast |
| Output current Imax.: | 100 mA |
| 1) Limit values: operation in short-circuit protected network max. 8 A 2) May not exceed or fall short of VS tolerances 3) Without load 4) With light/dark ratio 1:1 5) Signal transit time with resistive load 6) Reference voltage DC 50 V | |
| Ambient data | |
| Ambient temperature: | Operation: -10 ... 55 C Storage: -25 ... 75 C |
| Shock load: | according to IEC 60068 |