DT20-P130B1000 Distance sensor with analog output
Sick DT20-P130B1000 Description
- Different measuring ranges from 90 mm ... 1,000 mm
- Repeatability up to 1.5 mm
- Infrared sender, which is not visible to the human eye
- Analog and switching output provide distance and out of range information
- Plug and play sensor that is factory-programmed based on customer specifications
- High output rate - distance outputs are provided every millisecond
- Rugged, metal housing
- Fast, easy commissioning based on customer-specific presets saves time
- Tamper-proof sensor concept ensures high machine availability
- Inconspicuous and therefore non distracting by use of infrared light
- High ambient light immunity increases machine availability
- Solid, IP 67-rated metal housing permits operation in harsh environments, making the sensor suitable for a wide range of applications
Your benefits
| Performance | |
| Output rate: | 1 ms |
| Light source: | LED, infrared |
| Typ. light spot size (distance): | 15 mm x 15 mm (at 1 m) |
| Additional features: | Customer specific scaled measuring range, Plug & Play, Switching output to monitor the measuring range |
| Response time: | 15 ms |
| Measuring range 90 % remision: | 100 ... 1,000 mm |
| Measuring range 6 % remission: | 100 ... 820 mm |
| Measuring range 18 % remission: | 100 ... 1,000 mm |
| Resolution 6 % ... 90 %: | 2 mm |
| Accuracy 6 % ... 90 % remission: | 4 mm ... 7 mm 1) |
| Repeatability 6 % ... 90% remission: | 3 mm |
| 1) See accuracy diagram | |
| Interfaces | |
| Analog current outputs (max. load): | 1x 4 mA ... 20 mA (≤ 300 Ω) |
| Switching outputs (max. output current): | 1 x PNP (100 mA) 1) |
| 1) PNP: HIGH = Vs - (< 2 V), LOW = 0 V | |
| Mechanics/electronics | |
| Supply voltage Vs: | DC 10 V ... 30 V |
| Power consumption: | ≤ 1.5 W 1) |
| Warm up time: | ≤ 30 min |
| Housing material: | Metal |
| Connection type: | Connector M12, 5-pin |
| Indication: | 2 x LED |
| Initialization time: | ≤ 250 ms |
| Typ. weightwithout cable: | 135 g |
| Residual ripple: | ≤ 5 Vpp 2) |
| 1) Without load 2) May notfall or exceed short of VS tolerances Limit values, reverse-polarity protected, operation in short circuit protected network, max. 8 A | |
| Ambient data | |
| Enclosure rating: | IP 65 |
| Ambient temperature: | Operation: -25 ... 55 C Storage: -40 ... 75 C |
| Vibration resistance: | EN 60068-2-6 / -2-64 |
| Protection class: | II |
| Shock resistance: | EN 60068-2-27 / -2-29 |
| Average service life laser (MTTF at 25 C): | 100,000 h |
| Typ. temperature drift: | 0.25 mm/K |
Contact Us