Add To Cart
share
Sick DS30-N1253 Overview
DS30-N1253 DISTANCE SENSOR
Sick DS30-N1253 Description
- Measuring range up to 2,000 mm on black and white
- Measuring range up to 3,000 mm on gray and white
- Time-of-flight technology provides best suppression of any object in the background (up to 150 m)
- Minimal black/white shift ensures precise and reliable switching
- Models with 1, 2 and 3 switching outputs available for maximum flexibility
- Operating temperature from -40 C to +55 C
- Precise, reliable detection of objects - regardless of color - ensures a reliable process
- Small housing enables fast, easy integration into any system
- Reliable background suppression and high ambient light immunity increase productivity by eliminating false trips and machine down times
- Cost-efficient design and high sensor performance offer low initial costs and ensures exceptional economic benefits over the sensor lifetime
- Wide temperature range makes sensor suitable for several applications even cold storage warehouses
- State-of-the-art VCESL laser offers an extended lifetime of 100,000 h, increasing the overall sensor service life
- Multiple switching points enable up to three tasks for the price of one sensor
Your benefits
| Performance | |
| Response time: | 20 ms |
| Switching frequency: | 25 Hz |
| Light source: | Laser, infrared 1) |
| Laser protection class: | 1 (EN 60 825-1) |
| Typ. light spot size (distance): | 20 mm x 20 mm (at 2 m), At 2 m |
| Resolution 6 % ... 90 %: | 10 mm 2) |
| Measuring range 6 % ... 90 % remission: | 200 mm ... 2,000 mm |
| Service life: | 100,000 h |
| 1) Wave length: 850 nm 2) Teach resolution | |
| Interfaces | |
| Switching output: | 2x NPN (100 mA) 1) 2) |
| Teach input: | 1x ext. Teach |
| 1) Output Q short-circuit protected 2) NPN: HIGH = VS, LOW ? 2 V | |
| Mechanics/electronics | |
| Supply voltage Vs: | DC 10 V ... 30 V 1) |
| Residual ripple: | ≤ 5 Vpp 2) |
| Warm up time: | ≤ 5 min |
| Connection type: | Connector M12, 5-pin |
| Indication: | 2x LED |
| Weight: | 120 g |
| 1) Limit values, reverse-polarity protected, operation in short-circuit protected network, max. 8 A 2) May not fall short of or exceed VS tolerances | |
| Ambient data | |
| Enclosure rating: | IP 65 |
| Protection class: | II 1) |
| EMC: | EN 60947-5-2:1998-10 + A1:1999-08 + A2:2004-02, EN 61000-6-2:2005-08, EN 61000-6-3:2001-10 + A11:2004-07 |
| Ambient temperature: | Operation: -40 ... 55 C Storage: -40 ... 75 C |
| 1) Reference voltage DC 50 V | |
Contact Us