f Sick AOD5-P1 (6035985)- A&S Automation Co., Ltd
 
Home / Sensors / Sick Sensor / Sick AOD5-P1 (6035985)

Add To Cart
share


Sick AOD5-P1 Overview



AOD5-P1 OD Precision Amplifier Unit, PNP

Sick AOD5-P1 Description



  • Many measurement ranges from 24 ... 26 mm up to 300 700 mm
  • CMOS receiving element for measurement independent of surface
  • High measuring accuracy and frequency
  • Glass thickness measurement with just one sensor head
  • Different light spot sizes
  • Integrated calculations for up to three sensors
  • Stand alone use via RS- 422
  • Your benefits

  • Non-contact measurement improves quality inspection during production
  • Non-surface dependent measurement algorithms ensure minimum machine downtime, regardless of surface gloss or color
  • Reduced processing times as a result of the high measuring frequency of up to 10 kHz
  • Simple, cost-effective solution for challenging measuring tasks due to a variety of sensor models
  • Optional stand-alone measurement via RS-422 means the OD Precision offers maximum performance at lower investment costs
  • High visibility LC display enables simple, cost-effective setup
  • Range of interfaces for simple integration into an existing production environment

Performance
Output rate:10 kHz
Additional features:16 memory banks, Anti interference mode, Arithmetic calculations, Automatic sensitivity adjustment, Set hysterisis, Selectable measuring frequency (automatic / 0.1 ... 3.2 ms), Frequency filters, Glass thickness measurement, Hold functions, Peak measurement, Manual sensitivity adjustment, Averaging settings 1 ... 4,096 x, Scaling of analog outputs, Set levels of switching outputs, Switching window, Peak to peak measurement, Bottom measurement, Timer functions
System part:OD Precision controller
Note:Measuring range, accuracy, response time etc. depend on used sensor heads (see associated products)
Interfaces
In- and outputs:PNP
Analog current outputs (max. load):3 x 4 ... 20 mA (≤ 300 Ω)
Analog votage outputs (min. load):3 x -10 ... +10 V (≥ 10 kΩ)
Resolution analog outputs:16 Bit
Laser off inputs:3x (High = Us, Low = ≤ 2.8 V) 1)
Data interfaces:RS-232
USB
Switching outputs (max. output current):5x (100 mA / High = Us -(< 2 V), Low = 0 V)
Error output (max. output current):3x (100 mA / High = Us -(< 2 V), Low = 0 V) 2)
Reference inputs:4x (High = Us, Low = ≤ 2.8 V) 3)
Inputs for memory bank selection:4x (High = Us, Low = ≤ 2.8 V) 4)
Hold inputs:5x (High = Us, Low = ≤ 2.8 V) 5)
1) 2) 3) 4) 5) With use of external 50-pin terminal (accessories)
Mechanics/electronics
Supply voltage Vs:DC 12 V ... 24 V , -5%/+10%
Power consumption:≤ 10.8 W 1)
Warm up time:<= 5 min
Housing material:Polycarbonat and nylon 66
Connection type:Terminal board
Indication:LCD display
Typ. weightwithout cable:550 g
1) When connected with three sensor heads, incl. analog current output
Ambient data
Enclosure rating:IP 20
Ambient temperature:Operation: -10 ... 40 C
Storage: -20 ... 60 C
Max. rel. humidity (not condensing):35 % ... 95 %
Vibration resistance: 10 Hz ... 55 Hz, Amplitude 1.5 mm, 2 h for axes XYZ
Shock resistance:20G
Protection class:III