Sick WSE4S-3N1330H Description
- Hygienic designed stainless steel housing and accessories (316L/1.4404)
- Hygienic mounting using M12-adapter thread or D12-adapter shaft
- IP 66, IP 67, IP 68 and IP 69K enclosure rating and Ecolab certified
- Resistant to a variety of common cleaning and disinfection agents
- Stainless steel teach-in pushbutton with a metal membrane
- PinPoint LED technology provides a highly visible laser-like light spot
- Smooth hygienic housing and accessories with no grooves or crevices eliminates the potential for bacteria to grow, providing a more hygienic solution.
- Long service life in harsh conditions ensures less downtime and fewer replacement costs
- Quick and easy adjustment via a stainless steel metal membrane teach-in pushbutton
- Quick and easy alignment due to highly visible PinPoint emitter LED
Your benefits
| Features | |
| Dimensions (W x H x D):: | 15.25 mm x 48.6 mm x 22.15 mm |
| Sensing range max.: | 0 m ... 5 m 1) |
| Sensing range: | 0 m ... 4.5 m |
| Housing desig (light emission): | Cuboid, Slim |
| Light source: | PinPoint LED 2) |
| Type of light: | visible red light |
| Wave length: | 650 nm |
| Sensor/detection principle: | Through-beam photoelectric sensor |
| Light spot (distance): | O 130 mm (2 m) |
| 1) PL80A 2) Average service life 100,000 h at Ta = +25 C | |
| Mechanics/electronics | |
| Enclosure rating: | IP 66 IP 67 IP 68 IP 69K |
| Supply voltage: | 10 V DC ... 30 V DC 1) |
| Residual ripple: | < 5 Vpp 2) |
| Power consumption: | ≤ 20 mA 3) |
| Switching output: | NPN, light switching |
| Output current Imax.: | ≤ 100 mA |
| Response time: | < 0.5 ms 4) |
| Switching frequency: | 1,000 Hz 5) |
| Connection type: | Cable, 3-wire, 2 m 6) |
| Cable material: | PVC |
| Conductor cross-section: | 0.14 mm2 |
| Protection class: | III |
| Circuit protection: | A B C 7) 8) 9) |
| Weight: | 80 g |
| Housing material: | Edelstahl 316L |
| Ambient temperature, operation: | -35 C ... 70 C -35 C ... 60 C 10) |
| Ambient temperature, storage: | -35 C ... 75 C |
| Test input sender off: | TE to 0 V |
| 1) Limit values, reverse-polarity protected, operation in short-circuit protected network, max. 8 A 2) May not exceed or fall short of VS 3) Sender 4) Signal transit time with resistive load 5) With light/dark ratio 1:1 6) Do not bend below 0 C 7) A = VS connections reverse-polarity protected 8) B = inputs and output reverse-polarity protected 9) C = interference suppression 10) At UV ? 24 V and IA < 30 mA | |