f Sick UM18-20014 (6037880)- A&S Automation Co., Ltd
 
Home / Sensors / Sick Sensor / Sick UM18-20014 (6037880)

Add To Cart
share




Sick UM18-20014 Overview



Ultrasonic sensor double sheet detection UM18-20014 Sender / Receiver 2 switching outputs NPN

Sick UM18-20014 Description



  • Double-sheet detection of foils, metal sheets and thin corrugated cardboard
  • Operational area 40 mm +/- 3 mm
  • Automatic adjustment, plug and play operation
  • Color- independent detection
  • Two PNP outputs for double and miss-fed sheets
  • Your benefits

  • Increased quality and productivity through reliable double sheet detection
  • Fast commissioning since sensor does not require calibration or teaching
  • Reliable detection of transparent foils, various paper types and thin metal sheets provide application flexibility

Performance
Resolution:Double-sheets not completely glued together
Response time 1):2.5 ms / 6.5 ms
Typ. ultrasonic frequency:400 kHz
Installation distance sender - receiver:37 mm ... 43 mm
Blind zone:7 mm in each case from sender and receiver
Permissible angle deviation: 45 perpendicular to sheet
Detectable materials:Paper grams per square meter: 20 ... 1,200 g/m2
Metal-laminated sheets and films: <=≤ 0.4 mm
Self-adhesive films, metal sheets: <=≤ 0.3 mm
Corrugated cardboard:
Ultra-fine corrugated cardboard
1) Dependent on signal at control input: Vs < DC 5 V = 2.5 ms / Vs > DC 9 V = 6.5 ms
Interfaces
Time delay off::10 ms
Switching outputs (max. output current) 1) 2) 3):2 x NPN (500 mA)
Control inputs:1 x
1) Output Q short-circuit protected 2) Q1: switching output double sheet, Q2: switching output mis-fed sheet, normally closed 3) NPN: HIGH = < 2 V, LOW = Vs
Mechanics/electronics
Supply voltage Vs:DC 20 V ... 30 V
Power consumption 1):≤ 1.35 W
Initialization time:< 300 ms
Housing material 2):Brass nickel-plated
Connection type:Connection cable: 2 m, 5-pin, PVC
Cable sender: 1.2 m, connector 2-pin, PVC
Cable receiver: 1 m, connector 2-pin, PVC
Indication:Dual-LED
Typ. weightwith cable:280 g
1) Without load 2) Ultrasonic transducer: polyurethan foam, glass epoxy resin Limit values, reverse-polarity protected, operation in short circuit protected network, max. 8 A
Ambient data
Enclosure rating:IP 67
Ambient temperature:Operation: 5 ... 60 C
Storage: -40 ... 85 C