Add To Cart
share
Sick THTS-1AA540756MZ Description
- Pt100 element, accuracy class A (IEC 60751)
- Measuring ranges -50 C ... +150 C and -50 C +250 C
- Wetted parts: Corrosion-resistant stainless steel 316L/1.4435, Ra ≤ 0.8 m
- Various hygienic process connections and insertion lengths
- Pt100 (4-wire) or 4 mA 20 mA (2-wire)
- Round connector M12 x 1
- Convenient system integration installation in narrow installation space possible through compact dimensions
- Safe, hygienic operation due to wetted parts made from high-grade stainless steel, hygienically-graded surface finish and a gap- and crevice-free design
- Rugged: Connection housing is easily cleaned and splash proof
- Quick and safe installation
- Very good long-term stability, accuracy and linearity
- Quick response time
- Optimal solutions for individual requirements due to versatile configurability
Your benefits
| Features | |
| Measurement range: | -50 C ... 150 C |
| Sensor element: | Pt100 |
| Signal output and maximum ohmic load RA: | 4 mA ... 20 mA, 2-wire (RA ≤ (L+ - 10 V) / 0.023 A [Ohm]) |
| Performance | |
| Accuracy of sensor element: | class A according to IEC 60751 |
| Transmitter accuracy: | ≤ 0.2 % of span |
| Transmitter linearity: | ≤ 0.1 % of span |
| Response time: | Response time t50: ≤ 3.3 s response time t90: ≤ 9.7 s 1) |
| 1) Depending on sensor configuration, according to IEC 60751 | |
| Mechanics/electronics | |
| Process connection: | Conical coupling (DIN 11851) DN 40 with union nut |
| Insertion length/diameter of probe: | 75 mm / 6 mm |
| Housing material: | Stainless steel 1.4571 (316Ti) |
| Wetted parts: | stainless steel 1.4435 (316L), Ra ≤ 0.8 m |
| Electrical connection/enclosure rating 1): | Round connector M12 x 1, 4-pin / IP 68 and IP 69K |
| Electrical safety: | dielectric strength: 500 V AC Protection class: III Reverse polarity protection: L+ towards M |
| Supply voltage: | 10 V DC ... 35 V DC |
| Protection class III: | ![]() |
| CE-conformity: | 2004/108/EC, EN 61326-2-3 |
| Pressure resistance: | max. 40 bar |
| Maximum power consumption: | ca. 30 mA |
| 1) Enclosure rating IP per IEC 60529. The enclosure rating classes specified only apply while the pressure transmitter is connected with female connectors that provide the corresponding enclosure rating. | |
| Ambient data | |
| Ambient temperature: | -40 C ... 85 C |
| Storage and transport temperature: | -40 C ... 85 C |
| Vibration resistance according to IEC 60751: | 3 g |
| Shock resistance: | according to IEC 60751 |
| Relative humidity: | ≤ 95 % |
Contact Us
Hot Products