f Sick PHT-RB010S540S0AMS0Z (6039317)- A&S Automation Co., Ltd
 
Home / Sensors / Sick Sensor / Sick PHT-RB010S540S0AMS0Z (6039317)

Add To Cart
share


Sick PHT-RB010S540S0AMS0Z Overview



Pressure Transmitter PHT 0 ... 10 bar Accuracy +/- 0.5% of Span (BFSL) Female union nut DIN 11851 DN 40 -20... + 150degC Without sealing 4 ... 20 mA, 2-wire M12 x 1, 4-pin, IP 67 Supply Voltage 10...30 VDC Without certificates

Sick PHT-RB010S540S0AMS0Z Description



  • Robust and precise pressure measurement technology
  • Gauge measuring ranges from 0 ... 0.25 bar up to 0 25 bar
  • Available in 2 accuracy classes: <0.5% and <0.25% of span
  • Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra < 0.4 m
  • Wetted parts stainless steel 1.4435, housing stainless steel 1.4571
  • Large range of hygienic process connectors
  • Stainless steel housing and field housing with enclosure rating of up to IP 68
  • Your benefits

  • Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries
  • Safe hygienic operation through EHEDG and 3-A certifications
  • High reliability due to robust design and use of high-grade materials
  • Withstands CIP/SIP, ensuring high system availability and reliability
  • Transmitter housing is easily cleaned
  • Versatile configurability optimizes solutions

Features
Pressure type:Gauge pressure
Measurement range: 0 bar ... 10 bar
Process temperature: -20 C ... 150 C
Rated temperature:0 C ... 80 C
CE-conformity:
Performance
Accuracy:<= +/- 0.5 % (of span)
Non-linearity:0.2 % (Best Fit Straight Line (BFSL))
Response time:<= 10 ms
Mechanics/electronics
Process connection:Female union nut DIN 11851 DN 40
Wetted parts:Stainless steel 1.4435
Housing material:Stainless steel 1.4571
Enclosure rating:IP 67
Output signal:4...20 mA
Connection type:M12 x 1, 4-pin
Supply voltage:10 V DC ... 30 V DC
Electrical safety:Short-circuit protection: QA towards M, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M
Dielectric strength:500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions)
Protection class III:
Weight sensor: 500 g
Ambient data
Ambient temperature: -20 C ... 80 C
Shock load:500 g according to IEC 60068-2-27 (mechanical shock)
Vibration load:15g per IEC 60068-2-6 (vibration under resonance)