OD5-500W200 OD Precision Sensor head; Measurement range 300...700 mm; Wide light spot version
Sick OD5-500W200 Description
- Many measurement ranges from 24 ... 26 mm up to 300 700 mm
- CMOS receiving element for measurement independent of surface
- High measuring accuracy and frequency
- Glass thickness measurement with just one sensor head
- Different light spot sizes
- Integrated calculations for up to three sensors
- Stand alone use via RS- 422
- Non-contact measurement improves quality inspection during production
- Non-surface dependent measurement algorithms ensure minimum machine downtime, regardless of surface gloss or color
- Reduced processing times as a result of the high measuring frequency of up to 10 kHz
- Simple, cost-effective solution for challenging measuring tasks due to a variety of sensor models
- Optional stand-alone measurement via RS-422 means the OD Precision offers maximum performance at lower investment costs
- High visibility LC display enables simple, cost-effective setup
- Range of interfaces for simple integration into an existing production environment
Your benefits
| Performance | |
| Resolution 6 ... 90 %: | 10 1) |
| Measuring frequency: | 1.25 kHz |
| Output rate: | 10 kHz |
| Light source: | Red laser diode class 2 (II) 2) |
| Typ. light spot size (distance): | 1,000 m x 3,700 m 3) |
| Additional features: | Anti interference mode, Automatic sensitivity adjustment, Selectable measuring frequency (automatic / 0.1 ... 3.2 ms), Glass thickness measurement, Manual sensitivity adjustment, Averaging settings 1 ... 4,096 x |
| System part: | OD Precision sensor head |
| Note: | Stand alone use via RS-422 or use in combination with controller with more interfaces (see associated products) |
| Measuring range 6 ... 90 % remission: | 300 mm ... 700 mm |
| Repeatability 6 ... 90% remission: | 30 m 4) |
| Response time: | 0.8 ms 5) |
| Linearity 90 % remission: | 400 m 6) |
| 1) At set averaging 4096 2) Wave length 658 nm, max. output 1 mW 3) At 500 mm 4) At set averaging 4096 and constant conditions 5) Autom. sensitivity adjustment ? 2 ms / ? 16 ms (OD5-350... and OD5-500) 6) Equivalent to 0.05 % MS (for OD5-85...), 0.08 % MS (for OD5-25..., OD5-30W...and OD5-350...) or 0.1 % MS (OD5-T30...and OD5-500...), MS= measuring span: OD5-25...= 2 mm, OD5-30...= 10 mm, OD5-85...= 40 mm, OD5-350...= 200 mm, OD5-500...= 400 mm | |
| Interfaces | |
| In- and outputs: | PNP/NPN |
| Laser off inputs: | 1x (PNP: High = Us, Low = ≤ 2.8 V, NPN: High = ≤ 2.8 V, Low = Us) |
| Data interfaces: | RS-422 |
| Mechanics/electronics | |
| Supply voltage Vs: | DC 12 V ... 24 V , -5%/+10% |
| Power consumption: | ≤ 1.1 W |
| Warm up time: | <= 5 min |
| Housing material: | Aluminum and glass |
| Connection type: | 0.5 m pig tail with connector 1) |
| Indication: | LEDs |
| Typ. weightwithout cable: | 250 g |
| 1) Extenable by cable to max. 50 m | |
| Ambient data | |
| Enclosure rating: | IP 67 |
| Ambient temperature: | Operation: -10 ... 40 C Storage: -20 ... 60 C |
| Max. rel. humidity (not condensing): | 35 % ... 95 % |
| Vibration resistance: | 10 Hz ... 55 Hz, Amplitude 1.5 mm, 2 h for axes XYZ |
| Shock resistance: | 50 G |
| Protection class: | III |
| Typ. ambient light safety: | artificial light: >=3,000 Sunlight: >=10,000 |