Add To Cart
share
Sick OD2-N120W60U2 Overview
OD2-N120W60U2 Displacement Sensor OD Value: 60?180mm measurement range; 0?10V; 2x Q; DC 18...24V; NPN; 2m cable
Sick OD2-N120W60U2 Description
- Several measurement ranges from 26 ... 34 mm to 100 400 mm
- CMOS receiving element for measurement independent of surface, brightness or color
- Fast setup, LED-based user interface
- Wide range of models and four different output styles
- Safe, Class II laser technology for precise measurement of very small objects
- Compact stand-alone device
- Excellent price-performance ratio
- Reliable measurement independent of surface, minimizes machine downtime
- Extremely simple sensor teach-in makes setup faster and more cost-effective
- Minimal space requirements and less wiring due to its compact, stand-alone design
- Many measurement ranges and output interfaces make it ideal for cost-effective integration into any production environment - ideal for OEMs
- Low investment costs make consistent, regular quality inspection possible
- Non-contact measurement technology from a safe distance allows the inspection to be carried out directly during the production process without the need for recalibration
- Wear and damage-free inspection, due to non-contact measurement
Your benefits
| Performance | |
| Resolution 6 ... 90 %: | 30 1) |
| Measuring frequency and output rate: | 2 kHz |
| Light source: | Red laser diode class 2 (II) 2) |
| Typ. light spot size (distance): | 1 mm x 1.5 m 3) |
| Additional features: | Automatic sensitivity adjustment, Teach-in of analog outputs, Teach-in of switching outputs, Invertable analog output, Invertable switching output, Averaging settings 1 ... 64x, Multi functional input: laser off, external teach, trigger, Switching window |
| Measuring range 6 ... 90 % remission: | 60 mm ... 180 mm |
| Repeatability 6 ... 90% remission: | 90 m 4) |
| Response time: | 1 ms 5) |
| Accuracy 6 ... 90 % remission: | 300 m 6) 7) |
| 1) At set averaging medium (10 / 13 ms) 2) Wave length 650 nm, max. output 1 mW 3) At 120 mm 4) At set averaging medium and constant conditions 5) Autom. sensitivity adjustment ? 4 ms 6) Equivalent to 0.25 % MS, MS= Measuring span: OD2-_120...= 120 mm 7) Linearity for 90 % remission is equivalent to 0.1 % MS | |
| Interfaces | |
| In- and outputs: | NPN |
| Analog votage outputs (min. load): | 1 x 0 ... 10 V (≥ 10 kΩ) |
| Resolution analog outputs: | 16 Bit |
| Switching outputs (max. output current): | 2x (100 mA / High = Us, Low ≤ 2 V) |
| Multi functional inputs: | 1x (High = ≤ 2.8 V, Low = Us) 1) |
| 1) Response time ? 3 ms | |
| Mechanics/electronics | |
| Supply voltage Vs: | DC 18 V ... 24 V , -5 % / +10 % |
| Power consumption: | ≤ 2.88 W 1) |
| Warm up time: | <= 5 min |
| Housing material: | PBT and PMMA |
| Connection type: | Cable 2 m |
| Indication: | Distance bar graph |
| Typ. weightwithout cable: | 70 g |
| 1) Excl. load, incl. current output | |
| Ambient data | |
| Enclosure rating: | IP 67 |
| Ambient temperature: | Operation: -10 ... 40 C Storage: -10 ... 60 C |
| Max. rel. humidity (not condensing): | 0.35 % ... 0.95 % |
| Vibration resistance: | 10 Hz ... 55 Hz, Amplitude 1.5 mm, 2 h for axes XYZ |
| Shock resistance: | 50 G |
| Protection class: | III |
| Typ. ambient light safety: | artificial light: >=3,000 Sunlight: >=10,000 |
Contact Us