Registration Control Scanner NT8-02412 lens No.24 (1001324) lamp 4,5V (1001019)

Sick NT8-02412 Description



  • White light source
  • Light- or dark-switching selectable
  • Rapid response times
  • Adjustable switching threshold

Features
Dimensions (L x W x H):58.8 mm x 76 mm x 30 mm
Sensing distance 1):9 mm
Sensingdistance tolerance: 2 mm
Light source 2):Incandescent lamp white
Light emission:Long and short side of housing, exchangeable
Light spot size:1.5 mm x 3.5 mm
Light spot direction 3):Vertical
Supply voltage lamp:4,5 V 10%
Power consumption lamp:840 mA
Adjustment:Manual adjustment, potentiometer
Function:Light/dark switching
1) From front edge of lens 2) Average service life of 10,000 h at TA = + 25 C 3) In relationto long side of housing
Mechanics/electronics
Supply voltage Vs:DC 10 V ... 30 V
Residual ripple:≤ 5 Vpp
Power consumption 1):< 50 mA
Switching frequency 2):10 kHz
Response time 3):> 50 s
Switching output:NPN: HIGH = approx.VS/ LOW ≤ 2 V
Switching output:NPN
Connection type:2 m cable without plug 4)
Protection class 5):II
Circuit protection:Output Q short-circuit protected, Interference suppression, VS connections reverse-polarity protected
Enclosure rating:IP 67
Weight:ca. 300 g
Housing material:Die-cast zinc
Output current Imax.:200 mA
1) Without load 2) With light/dark ratio 1:1 3) Signal transit time with resistive load 4) Below 0 C no deformation of cable 5) Reference voltage 50 V DC
Ambient data
Ambient temperature:Operation: 0 ... 55 C
Storage: -25 ... 85 C
Shock load:according to IEC 60068