Add To Cart
share
Sick MZT6-03VPS-KWX Overview
MZT6-03VPS-KWX Magnetic cylinder sensor, DC 3-wire, PNP, NO, cable 2m, PVC EX 3G EEx nA II T4X EX 3D T100 Grad IP67 >> We would like to point out relating to the Directive 94/9/EC (ATEX) and EN13980 that you are responsible for the traceability of the ord
Sick MZT6-03VPS-KWX Description
- ATEX 3D/ 3G and ATEX 3G
- Compact housing design
- Proprietary GMR-ASIC technology ensures precise switching and low hysteresis
- Enclosure rating: IP 68 / IP 69K
- Combined fixing screw
- LED function indicator
- For all commonly used cylinders with T-slots, e.g., Festo or SMC and it can be applied to multiple cylinders types such as round, tie-rod, integrated profile or dove-tail cylinders with mounting brackets
- Best-in-class switching performance for precise piston position
- Highly resistant to shock and vibration enlarging sensor life time
- Drop-in T-slot mounting from above makes assembly easy
- Easy installation with Allen wrench or flat head screwdriver
- Resistant to leaks, ensuring reliability
Your benefits
| Features | |
| Switching frequency: | 1,000 Hz |
| Connection type: | Cable, 3-wire, 2 m |
| Switching output: | PNP |
| Output function: | NO |
| Electrical wiring: | DC 3-wire |
| Sensing face: | Front |
| Switching mode: | NO |
| According to EN40050 | |
| Mechanics/electronics | |
| Enclosure rating: | IP 68 IP 69K 1) |
| Cylinder types: | T-slot |
| Cylinder types with adapter: | Profile cylinder, Roundbody cylinder, Schwalbenschwanzzylinder, SMC rail cylinder CDQ2 (T-Slot), SMC rail cylinder ECDQ2 (T-Slot), Tie rod cylinder |
| Housing length: | 31.5 mm |
| Supply voltage: | 18 V DC ... 30 V DC |
| Power consumption: | ≤ 10 mA 2) |
| Voltage drop: | ≤ 2.2 V |
| Continuous current Ia: | ≤ 70 mA |
| Hysteresis: | > 0.5 mT |
| Repeatability: | ≤ 0.1 mT 3) |
| EMC: | According to EN 60947-5-2 |
| Cable material: | PVC |
| Conductor cross-section: | 0.14 mm2 |
| Reverse polarity protection: | ![]() |
| Short-circuit protection: | ![]() |
| Housing material: | Plastic |
| Sensing area material: | Plastic |
| Ambient temperature, operation: | -20 C ... 45 C |
| Shock/vibration stress: | 30 g, 11 ms/10 ... 55 Hz, 1 mm |
| Power-up pulse suppression: | ![]() |
| Response sensitivity: | 2.6 mT |
| Hazardous area category: | 3D, 3G |
| Marking of the unit: | Ex II 3D T100 C IP 67, Ex II 3G EEx nA II T4 X |
| Overrun distance typ.: | 3 mm |
| 1) According to EN40050 2) Without load 3) Ub and Ta constant | |