LFV200-XASGACPV LEVEL SWITCH Overfill protection acc. WHG, 0...100C, G1" A, Contactless electronic switch 20...253VAC/DC, Housing 316L, incl. plug acc. DIN42650, IP65

Sick LFV200-XASGACPV Description



  • Housing made of 316L stainless steel
  • Two electrical output versions available
  • Commissioning without filling
  • Process temperature up to 150 C
  • Immune to deposit formation
  • Very high repeatability
  • Aseptic versions according to EHEDG and FDA available, CIP and SIP resistant
  • Your benefits

  • Easy installation and commissioning, no calibration necessary
  • Easy operation and integration, saves time
  • Maintenance-free sensor, reduces downtime
  • Testing in place possible - no mounting required, which reduces installation time
  • Flexible and robust system for a multitude of applications
  • Universal technology works in all kinds of liquids

Features
Medium:Fluids
Measurement:switch
Measurement range:40 mm
Probe length:40 mm
Process pressure: -1 bar ... 64 bar
Process temperature: -40 C ... 100 C
Fill material density:0.7
Silicon free:-
Authorizations:WHG approval
WHG approval:
Performance
Repeatability:1
Viscosity:0.1 mPas ... 10,000 mPas
Resolution:≤ 1 mm
Accuracy of sensor element: 2 mm
Mechanical data
Housing material:Stainless steel 316L, PEI
Process connection:G 1 A PN 64
Wetted parts:316L(optional Ra < 0.8 m)
Aseptic:-
Electrical data
Supply voltage: 20 V AC/DC ... 253 V AC/DC
Power consumption:≤ 4.2 mA
Initialization time:3 s
Hysteresis:2 mm
Connection type:Valve plug DIN 43650
Response time:500 ms
Output current:< 250 mA
Capacitive load:100 H
Inductive load:≤ 1 H
Enclosure rating:IP 65
Temperature drift:0,03 mm/K
Protection class:1
Ambient data
Ambient temperature, operation:-40 C ... 70 C
Ambient temperature, storage: -40 C ... 80 C