SICK WLL260-S240 Overview
WLL260-S240
SICK WLL260-S240 Description
- Fiber optic cable for proximity version
- Fiber optic cable for through-beam version
- Mounting bracket for photoelectric sensor included in delivery
- Light/dark-switching
- M12 connector or easily accessible terminal connection compartment
- Models for 10 - 30 V DC or 12 - 240 V DC/ 24 240 V AC voltage supply
- Detection of objects in the tightest of spaces with various fiber-optic cables
- Controls are protected under a cover
- Easily accessible terminal connection compartment simplifies electrical connection
- Assembly compatibility - DC devices and DC/AC devices available in the same design
Your benefits
| Features | |
| Dimensions (W x H x D):: | 25 mm x 77.8 mm x 63 mm |
| Sensing range max.: | 0 mm ... 65 mm, proximity system, LIS/LIB 0 mm ... 110 mm, proximity system, with special fibre-optic cable 0 mm ... 800 mm, through-beam system, LIS/LIB 1) 2) |
| Sensing range: | 0 mm ... 50 mm, proximity system, LIS/LIB 0 mm ... 90 mm, proximity system, with special fibre-optic cable 0 mm ... 700 mm, through-beam system, LIS/LIB |
| Light source: | LED 3) |
| Type of light: | visible red light |
| Enclosure rating: | IP 66 |
| Adjustment: | adjustable |
| Sensitivity adjustment: | Adjustable Potentiometer, 270 |
| Indication: | LED |
| Light spot diameter (distance): | depends on scanning range |
| 1) 2) Object with 90 % reflectance (referred to standard white DIN 5033) 3) Average service life 100,000 h at Ta = +25 C | |
| Mechanics/electronics | |
| Supply voltage: | 12 V DC ... 240 V DC 24 V AC ... 240 V AC 1) 2) |
| Switching output: | Relay, light/dark-switching, selectable via light/dark selector, NO, electrically isolated 3) |
| Response time: | ≤ 20 ms |
| Switching frequency: | 25 Hz with light/dark ratio 1:1 |
| Connection type: | Cable gland |
| Protection class: | II 4) |
| Circuit protection: | A C 5) 6) |
| Housing material: | ABS |
| Weight: | 120 g |
| Items supplied: | mounting bracket BEF-W260 |
| Power consumption: | ≤ 5 VA |
| Switching current (switching voltage): | 3 (240) 3 (30) |
| Usage category: | AC-15, DC-13, according to EN 60947-1 |
| 1) 2) +-10 % 3) Provide suitable spark supression for inductive or capacitive loads 4) 5) A = VS connections reverse-polarity protected 6) C = interference suppression | |
| Ambient data | |
| Ambient temperature, operation: | -25 C ... 55 C |
| Ambient temperature, storage: | -40 C ... 70 C |