Sick MM12-60ANS-ZCK Overview
MM12-60ANS-ZCK Magnetic proximity sensor sn=60mm, axial, connector M12 DC-3-wire, NPN, NO
Sick MM12-60ANS-ZCK Description
- Detection of magnets
- Operating distances up to 90 mm or more based on the magnet strength
- High switching frequency
- Short-circuit, reverse polarity and power-up pulse suppression protection
- Robust nickel-plated brass housing with fine thread M12 x 1 mm
- IP 67 enclosure rating
- Cylindrical design
- PNP or NPN output
- Non-contact operation eliminates interference from dirt, dust and vibrations, increasing sensor life and reducing maintenance costs
- Space-saving installation due to small design
- Large operating distances with reliable switching increase throughput
- Non-contact, universal detection through several substances, including plastic containers and pipes protective PTFE walls and non-magnetic metal walls
Your benefits
| Features | |
| Sensing range Sn: | 60 mm |
| Switching frequency: | 1,000 Hz |
| Connection type: | Connector M12, 4-pin |
| Switching output: | NPN |
| Output function: | NO |
| Electrical wiring: | DC 3-wire |
| Enclosure rating: | IP 67 1) |
| Switching mode: | NO |
| 1) According to EN60529 | |
| Mechanics/electronics | |
| Design: | cylindrical |
| Thread size: | M12 |
| Housing length: | 46 mm |
| Supply voltage: | 10 V DC ... 30 V DC |
| Residual ripple: | ≤ 10 % 1) |
| Power consumption: | ≤ 10 mA 2) |
| Voltage drop: | ≤ 2 V 3) |
| Continuous current Ia: | ≤ 200 mA |
| Hysteresis: | 1 % ... 10 % |
| Repeatability: | ≤ 1 % 4) |
| EMC: | According to EN 60947-5-2 |
| Max. tightening torque: | 15 Nm |
| Reverse polarity protection: | ![]() |
| Short-circuit protection 5): | ![]() |
| Housing material: | Metal, Nickel-plated brass |
| Special Design: | Short version |
| Power-up pulse suppression: | ![]() |
| Time delay before availability: | ≤ 20 ms |
| Ambient temperature, operation: | -25 C ... 75 C |
| Shock/vibration stress: | 30 g, 11 ms/10 ... 55 Hz, 1 mm |
| Temperature drift (of sr):: | 10 % |
| 1) Of VS 2) Without load 3) At Ia max 4) Von Sr (VS und Ta constant) 5) Pulsed | |